Live situation of dynamic balance of ZL-220H field balance instrument
Key words:
Classification:
- Product Description
- Scope of application
- Technical parameters
- Product Video
- File Download
-
- Commodity name: Live situation of dynamic balance of ZL-220H field balance instrument
Overview:
ZL-220H field balancer is a special instrument developed by our company, which uses embedded computer to measure dynamic balance. It uses advanced digital and analog circuits, and perfectly combines automatic tracking, digital filtering, automatic gain control and other technologies with self-developed software. At the same time, the software absorbs many years of experience in the use of production testers, so that the operation is simple, fast, accurate, stable, clear at a glance the operation of the keyboard, convenient storage, take data, so that the general operator just a little pointing, will be able to master the method of use. The electrical measurement system can be widely used in the measurement of ultra-small workpieces, and it is more comfortable for the measurement of large workpieces. Suitable for use with various types of dynamic balancing machines.
Technical parameters:
1
Maximum number of measurement channels
Two
2
Workpiece dynamic balance speed
300-8000r/min
3
Dynamic balance primary reduction rate URR
>85%
4
Maximum measurement time
10S
5
Power
180V/250V~50W
7
Overall dimensions (length * width * height)
350*350*200
8
Weight
4KG
9
Maximum mass of workpiece
No upper limit
10
Maximum diameter of workpiece
No upper limit
Note:
1. The specifications in the table are standard models, and the special requirements in the specifications shall be negotiated separately;
2. The speed in the table is approximate reference value;
3. The manufacturer reserves the right to modify the parameters of the table column. If there is any change, no further notice will be given.Scope of application:
Mainly suitable for balancing applications in rotating machinery such as fans, motors, machine tool spindles, water pumps, grinding wheels, etc.
It can be used to solve the problem of single-sided and double-sided balance on site, and can also be used for various balancing machines to correct the imbalance of rotating workpieces.
Operation mode:
Using the influence derivative method (test weight comparison method), after measuring the influence coefficient, the unbalanced weight (g) and its phase (degree) can be directly displayed.
Use environment:
Ambient temperature -10/40°C Ambient humidity <95% (no condensation) No strong corrosive gas or serious dust environment Main technical indicators:
It is used for field balance and can reach the required value of vibration speed when working speed is 300 r/min ~ 8000 r/min. Vibrometer can be used to test its workpiece.
For balancing machine in the case of wear is not serious electrical measurement system can reach the following indicators (according to national standards).
(1) Minimum achievable unbalance
- e m a r < 1 ~ 2gmm/kg (roller support method)
- e m a r < 0.5gmm/kg (V-groove support method)
The acceptance of the new machine before leaving the factory is higher than the above indicators.
(2) Primary reduction rate of dynamic balance: URR > 85%
(3) Maximum measurement time: <10 seconds
Description:
1. There is one suction seat sensor for single-sided balance. Customers who need spare parts can purchase another one. Two suction seat sensors are provided for double-sided balance. Customers who have a balancing machine can also use the two sensors on the machine for interface matching and debugging.
2. A row of indicator lights at the bottom of the keyboard are used for signal level indication. When the imbalance is large, the light moves to the left, and when the imbalance is small, the right moves to the starting point. When the calibration is carried out, the indicator light should be in the middle or right position. When the light moves to the left top, it indicates that the imbalance is large.
3. When the input speed is consistent with the actual operation, the electrical measuring box program is opened for measurement. The speed is inconsistent, indicating a stop or memory.
Overview:
ZL-220H field balancer is a special instrument developed by our company, which uses embedded computer to measure dynamic balance. It uses advanced digital and analog circuits, and perfectly combines automatic tracking, digital filtering, automatic gain control and other technologies with self-developed software. At the same time, the software absorbs many years of experience in the use of production testers, so that the operation is simple, fast, accurate, stable, clear at a glance the operation of the keyboard, convenient storage, take data, so that the general operator just a little pointing, will be able to master the method of use. The electrical measurement system can be widely used in the measurement of ultra-small workpieces, and it is more comfortable for the measurement of large workpieces. Suitable for use with various types of dynamic balancing machines.
Technical parameters:
1 |
Maximum number of measurement channels |
Two |
2 |
Workpiece dynamic balance speed |
300-8000r/min |
3 |
Dynamic balance primary reduction rate URR |
>85% |
4 |
Maximum measurement time |
10S |
5 |
Power |
180V/250V~50W |
7 |
Overall dimensions (length * width * height) |
350*350*200 |
8 |
Weight |
4KG |
9 |
Maximum mass of workpiece |
No upper limit |
10 |
Maximum diameter of workpiece |
No upper limit |
Note:
1. The specifications in the table are standard models, and the special requirements in the specifications shall be negotiated separately;
2. The speed in the table is approximate reference value;
3. The manufacturer reserves the right to modify the parameters of the table column. If there is any change, no further notice will be given.
Scope of application:
Mainly suitable for balancing applications in rotating machinery such as fans, motors, machine tool spindles, water pumps, grinding wheels, etc.
It can be used to solve the problem of single-sided and double-sided balance on site, and can also be used for various balancing machines to correct the imbalance of rotating workpieces.
Operation mode:
Using the influence derivative method (test weight comparison method), after measuring the influence coefficient, the unbalanced weight (g) and its phase (degree) can be directly displayed.
Use environment:
Ambient temperature | -10/40°C |
Ambient humidity | <95% (no condensation) |
No strong corrosive gas or serious dust environment |
Main technical indicators:
It is used for field balance and can reach the required value of vibration speed when working speed is 300 r/min ~ 8000 r/min. Vibrometer can be used to test its workpiece.
For balancing machine in the case of wear is not serious electrical measurement system can reach the following indicators (according to national standards).
(1) Minimum achievable unbalance
- e m a r < 1 ~ 2gmm/kg (roller support method)
- e m a r < 0.5gmm/kg (V-groove support method)
The acceptance of the new machine before leaving the factory is higher than the above indicators.
(2) Primary reduction rate of dynamic balance: URR > 85%
(3) Maximum measurement time: <10 seconds
Description:
1. There is one suction seat sensor for single-sided balance. Customers who need spare parts can purchase another one. Two suction seat sensors are provided for double-sided balance. Customers who have a balancing machine can also use the two sensors on the machine for interface matching and debugging.
2. A row of indicator lights at the bottom of the keyboard are used for signal level indication. When the imbalance is large, the light moves to the left, and when the imbalance is small, the right moves to the starting point. When the calibration is carried out, the indicator light should be in the middle or right position. When the light moves to the left top, it indicates that the imbalance is large.
3. When the input speed is consistent with the actual operation, the electrical measuring box program is opened for measurement. The speed is inconsistent, indicating a stop or memory.
Previous Page
Next Page
Previous Page
Next Page
Online Inquiry
Related Products